Epos VG-R206 Silent 188kva / 150kw Notstrom Aggregat Stromerzeuger Generator
Model: VG-R206
GeneratorSpecification
Performance Data | |
Model | VG-R206 |
Engine Brand | Ricardo |
Engine model | R6108ZLD/170kw |
Alternator | VG-274G/150kw |
Control system | AMF digital panel 6120U |
Starter motor voltage | 2 x 12V/80Ah |
Breaker | CHINT MCCB 3P 300A |
Fuel consum. @100% load | 47.6 L/h or 235g/kw.h |
Service | PRP | ESP |
Power(kVA) | 188kva | 206kva |
Power(kW) | 150kw | 165kw |
Rated speed ( r.p.m) | 1500 | |
Rated Outlet | 3PH 380V 50Hz | |
Rated Power factor | 0.8 @lagging | |
Rated Current | 285.6 Amps |
Dimension | |
Type | Soundproof |
Length (L) | 3000mm |
Width (W) | 1130mm |
Height (H) | 1700mm |
Net Weight | 1800kg |
Fuel Tank (L) | 255 L |
EMEAN Power gensets are compliant with ISO 9001 and CE standard, which include the following directives:
EN ISO 12100:2010, EN ISO 8528-13:2016,
EN 60204-1:2006+A1:2009+AC:2010,
EN 55012:2007+A1:2009
(1) PRP (Prime Power):
According to ISO8528-1, prime power is the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals. The permissible average power output during at 24 hours period shall not exceed 80% of the prime power. 10% overload available for governing purposes only.
(2) ESP (Standby Power):
According to ISO 8528-1, It is defined as the maximum power available, under the agreed operating conditions, for which the generating set is capable of delivering for up to 500 hours of operation per year (of which no more than 300 hours for continuous use) with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. No overload capability is available
Standard Features:
Brand new water cooled diesel engine
Brushless alternators (Class H, with AVR)
Working condition: 0 °C~+45 °C (Antifreeze system
needed if below 0°C)
Base frame fuel tank for continue 8-10hrs running Digital control panel with auto full protection
MCCB air circuit breaker with safety protection Residential silencer for silent type generator sets
Humanized design, simple operation, easy maintenance
All sets undergo a comprehensive testing pre delivery Peace of mind of one year warranty
Engine/MotorSpecification
Performance Data | |
Make | Ricardo |
Model | R6108ZLD |
Engine Type | In line Pump, |
Rated Output power | 170kw@1500RPM |
Max RPM, off load | ≤1575RPM |
Low idling speed | ≤500RPM |
Bore× stroke(mm) | 108*135 |
Compression Ratio | 17:1 |
Displacement | 7.41 L |
Fire order | 1-5-3-6-2-4 |
Oil capacity | 16 L |
Coolant capacity | 14.2 L |
Air Intake System | Turbocharged |
Fuel consumption | 47.6 L/h(100%), 35.7 L/h(75%), 23.8 L/h(50%) |
mean effective pressure | 1245 kPa |
Starter | 24V DC |
Fuel pump | Mechanical |
Cooling system | 50°C ambient radiator |
Exhaust gas temperature | ≤540°C |
AlternatorSpecification
Performance Data | |
Brand | Stamford Technology |
Model | VG-274G |
Technology | Brushless, 100% copper |
Rated power | 150KW @1500RPM |
Power factor(cosΦ ) | 0.8 |
Efficiency | 93.5% |
Insulation system | Class H |
Protection | IP21 |
Stator length | 340mm |
Rotor | Single bearing |
Winding Connections (standard) | Star/Y, 4 wires |
WINDING PITCH | TWO THIRDS |
WINDING LEADS | 12 |
Excitation system | Self-excited |
Coating | Vacuum impregnation |
Voltage regulator | A.V.R SX460 |
MAXIMUM OVERSPEED | 2250 Rev/Min |
ALTITUDE | ≤1000m |
Voltage Stabilized regulation | ≤±1.5% |
Voltage Instantaneous regulation | ≤±20% |
Voltage Recovery time (s) | ≤1 |
Voltage Fluctuation ratio | ≤1% |
Voltage Wave aberration ratio | ≤5% |
Frequency Stabilized regulation | ≤1%(adjustable) |
Frequency Instantaneous regulation | -10%~12% |
Frequency Fluctuation ratio | ≤1% |
Control Panel
Terminal and Electric System
CONTROL | MODULE | HGM6120N | FEATURES |
AMF (Automatic Mains Failure Module)
This module is used to monitor a mains supply and automatically start a standby generating set
Event logging and shutdown alarms STOP/RESET-MANUAL-AUTO-TEST-START METERING VIA LCD DISPLAY
Generator volts (L-L/L-N);
Generator amps (L1, L2, L3);
Generator frequency;
Engine hours run;
Engine oil pressure (psi and bar);
Fuel tank capacity level;
AND FAULT CONDITIONS Under/over speed; fail to start
High engine temperature; fail to stop
Low oil pressure; charge fail
Under/over generator volts; over current Under/over generator frequency; emergency stop Under/over mains frequency
Under/over mains voltage Low/high battery volts
CHNIT MCCB breaker 3P
Sealed 12/24V Dry battery 80A with Charger
mains volts (L-L/L-N); Generator (kVA and kW) ;
Generator (cos); Start battery (volts);
Engine speed (rpm); Engine temperature ( ̊C)
AUTOMATIC | SHUTDOWN |
300A ATS for auto start when utility power off
Canopy and Steel base
Ventilation parts are designed with modular Warranty principles
Soundproof and lined with sound reducing foam All metal canopy parts are painted by powderpaint Panel window
Lockable doors on front and back
Easy maintenance and operation
Easy lifting and moving
Exterior emergency stop push button
Steel chassis and anti-vibration pads
Base frame design incorporates an integral fuel tank
The generator can be lifted or pushed/pulled by the base frame carefully
Includes diesel level sensor information to the controller
Plywood case package
We shall provide a warranty of 12 months or 1200 hours from B/L date (whichever comes first), covering all manufacturing defects. We replace damaged parts caused by manufacturing faults or defected parts/materials, but exclude the damageable parts due to customer's incorrect man-made operation. After expiration, we still provides technical and spare parts support with cost for maintenance.